Updated on 01/04/26 by Mananjay MahatoShare on WhatsApp

1. Core Concept: Vapour Compression Refrigeration System (VCRS)

Both Window and Split ACs operate on the VCRS cycle.

  • Refrigerants used: R-22 (older), R-32, R-410A (High pressure), R-290 (Propane – Flammable).

  • The Four Main Stages:

    1. Compression: Low pressure, low temperature (LP/LT) vapour $\rightarrow$ High pressure, high temperature (HP/HT) vapour.

    2. Condensation: HP/HT vapour $\rightarrow$ HP/HT liquid (Heat rejected to outside).

    3. Expansion: HP/HT liquid $\rightarrow$ LP/LT liquid/vapour mix (Pressure drop).

    4. Evaporation: LP/LT liquid $\rightarrow$ LP/LT vapour (Heat absorbed from room).


2. Window Air Conditioner (Unitary System)

A self-contained unit where all components are housed in a single chassis.

Technical Components

  • Compressor: Usually Hermetically Sealed Reciprocating or Rotary type.

  • Condenser: Air-cooled, finned-tube type (located at the rear/outside).

  • Evaporator: Finned-tube type (located at the front/indoor side).

  • Expansion Device: Capillary Tube (Fixed orifice).

  • Fan Motor: Single motor with a Double-ended shaft. One end drives the Centrifugal Blower (Evaporator side), and the other drives the Propeller Fan (Condenser side).

Key Mechanic Facts

  • Air Circuit: Uses a “Ventilation Damper” to bring in a small amount of fresh air.

  • Slingshot Ring: The condenser fan has a ring that picks up condensate water from the base tray and splashes it onto the condenser coils to assist cooling (Sub-cooling).

  • Mounting: Requires a wall opening or window frame; higher vibration/noise because the compressor is inside the room perimeter.


3. Split Air Conditioner

Separates the “noisy” components from the “cooling” components.

System Division

  • Indoor Unit (IDU): Contains Evaporator coil, Filter, Cross-flow fan (Tangential fan), and Control PCB.

  • Outdoor Unit (ODU): Contains Compressor, Condenser coil, Propeller fan, and Expansion device (Capillary or EEV).

Installation/Technical Specs

    • Refrigerant Piping: Connected via “Suction Line” (larger diameter) and “Liquid/Discharge Line” (smaller diameter).

    • Flare Nut Joints: Critical point for leak testing using soap solution or electronic leak detectors.

    • Inverter Technology: Uses a Variable Frequency Drive (VFD) to change compressor speed. Unlike “On/Off” ACs, it doesn’t stop the compressor, saving 30-50% energy.

Shutterstock

4. Comparison for Competitive Exams

Feature Window AC Split AC
Installation Easier (single hole/window) Complex (requires copper piping & vacuuming)
Noise Level High (Compressor is nearby) Low (Compressor is outdoors)
Expansion Device Capillary Tube Capillary or Electronic Expansion Valve (EEV)
Efficiency Lower (limited coil size) Higher (larger condenser area possible)
Maintenance Easier (pull out the chassis) Harder (requires gas charging if leaks occur)

5. Important Exam Keywords & Troubleshooting

  • Evacuation: Removing air and moisture using a vacuum pump before gas charging. Moisture causes Capillary Choking (ice formation inside the tube).

  • Purging: Clearing air from hoses using a small amount of refrigerant.

  • Superheating: Ensuring only vapour enters the compressor to prevent Liquid Slugging (which breaks valves).

  • Short Cycling: AC turns on/off too rapidly. Causes: Oversized AC, dirty filters, or faulty thermostat.

  • Frost on Evaporator: Usually caused by Low Refrigerant or Restricted Airflow (dirty filters).

  • Pump Down: Moving all refrigerant into the Outdoor Unit (ODU) for repairs or shifting.


  • Anemometer: Measures air velocity at the grill.
  • Psychrometer: Measures Dry Bulb (DBT) and Wet Bulb (WBT) temperatures to check humidity.

  • Halide Torch / Electronic Leak Detector: Used for finding gas leaks.

  • Brazing: Joining copper tubes using Silver Solder and Oxy-Acetylene/LPG torch.

Pro-Tip for Exams: Always remember that in a Split AC, the Capillary Tube is almost always located in the Outdoor Unit to reduce noise of the refrigerant expansion inside the room.

12 Window AC/ Split AC