With reference to closed windings, state TRUE/FALSE for following statement:
1. The front pitch is always even.
2. The back pitch is always odd. (UPPCL TG-2, 09.11.2023, Shift-II)

  • 1-False, 2-True
  • 1-True, 2-True
  • 1-True, 2-False
  • 1-False, 2-False

Explanation:

  • Winding pitches –
    Both front pitch (YF) and back pitch (YB) should be odd.
    Back pitch (YB) is the distance between the two active sides of a coil on the back side of the armature.
    Front pitch (YF) is the distance between the first active side of the second coil and the second active side of the first coil.

The coil span of a full pitch winding for a six pole machine will be: (UPPCL TG-2, 8.11.2023, Shift-II)

  • 45 degree mechanical
  • 90 degree mechanical
  • 180 degree mechanical
  • 60 degree mechanical

Explanation:

  • Electrical and mechanical angle –
    Number of poles P = 6.
    Full pitch = 180° electrical.
    θelec = θmech × P/2
    180° = θmech × 6/2
    θmech = 60°

A D.C. machine, which of the following option is correct for the progressive winding? (UPPCL TG-2, 10.11.2023, Shift-I)

  • YB = YF
  • YB = YB + 1
  • YB < YF
  • YB > YF

Explanation:

  • Progressive winding –
    In a progressive winding, back pitch (YB) is greater than front pitch (YF).
    The winding advances only in the forward direction and the leads do not cross each other.
    Retrogressive winding runs in the opposite direction.
    In retrogressive winding, YB < YF and YC = –1.

What is the pitch factor of winding? (UPPCL TG-2, 08.11.2023, Shift-II)

  • Pitch factor = winding pitch × pole pitch
  • Pitch factor = winding pitch – pole pitch
  • Pitch factor = pole pitch / winding pitch
  • Pitch factor = winding pitch/pole pitch

Explanation:

  • Pitch factor –
    It is the ratio of the voltage induced in a short-pitch winding to the voltage that would be induced in a full-pitch winding.
    Kp = cos(α/2), where α is the short-pitch angle.
    Among the given options, winding pitch/pole pitch is the keyed relation.

In which type of machines the priority of the wave coil is given? (UPPCL TG-2, 07.11.2023, Shift-II)

  • High current and Low voltage
  • High current and High voltage
  • Low current and Low voltage
  • Low current and High voltage

Explanation:

  • Wave and lap winding –
    Wave winding is used for low current and high voltage.
    Lap winding is used for low voltage and high current.
    Lap winding is also called parallel or multiple winding and uses equalizer rings.
    In simplex lap winding, A = P.

The winding in which each slot has only one coil side is called? (UPPCL TG-2, 09.11.2023, Shift-II)

  • winding pitch
  • double layer winding
  • single layer winding
  • no winding

Explanation:

  • Single layer winding –
    Each slot contains only one coil side.
    Pole pitch = Z/P = number of conductors or slots / number of poles.

In one of the following winding all the coils are connected in series to form a progressive wave, and there are only two parts to the armature current regardless of the number of poles. It is called? (UPPCL TG-2, 10.11.2023, Shift-I)

  • Multiple winding
  • Simplex lap winding
  • Wave winding
  • Lap winding

Explanation:

  • Wave winding –
    All coils are connected in series to form a progressive wave.
    The armature current has only two paths, whatever the number of poles (simplex).
    It is used to obtain high voltage and low current.

In which type of winding, a long coil of sufficient length is first wound and then inserted in one slot and the reminder of the length is turned and inserted in the adjacent slots? (UPPCL TG-2, 09.11.2023, Shift-II)

  • Skein winding
  • Involutes coil winding
  • Chain winding
  • Basket winding

Explanation:

  • Skein winding –
    A large coil is wound and then installed in different stator slots.
    After one complete coil is placed, it is wrapped again into the slots.
    The remaining length is folded and fed in to form the coils.

From the given figure identify the type of winding- (UPPCL TG-2, 10.11.2023, Shift-I)

  • Duplex winding
  • Concentric winding
  • Simplex winding
  • Triplex winding

Explanation:

  • Simplex winding –
    In simplex lap winding, the number of parallel paths between the brushes equals the number of poles.
    The number of commutator segments equals the number of coils.

In which type of winding the coils overlap with each other? (UPPCL TG-2, 10.11.2023, Shift-I)

  • Basket winding
  • Chain winding
  • Diamond winding
  • Odd winding

Explanation:

  • Chain winding –
    In chain or flat loop over lap winding, the coils overlap each other.
    The number of coils per phase per pole is kept more than one.
    Coils are usually made in two sizes and placed side by side.
    The winding loops like a chain.
    It is used in single phase A.C. windings.

Name the winding in which the number of parallel paths between the brushes is thrice the number of poles? (UPPCL TG-2, 10.11.2023, Shift-I)

  • Simplex winding
  • Triplex winding
  • Concentric winding
  • Duplex winding

Explanation:

  • Triplex winding –
    The number of parallel paths is three times the number of poles (lap winding).
    The first end of a coil is connected to the first segment.
    The second end is connected to the fourth segment.

The end lead of the coil 1 is connected to the beginning of the coil placed at a distance equal to one pole pitch is called ________ (UPPCL TG-2, 10.11.2023, Shift-I)

  • Simple lap winding
  • Simple wave winding
  • Duplex lap winding
  • Duplex wave winding

Explanation:

  • Simple wave winding –
    The end lead of coil 1 is connected to the beginning of a coil about one pole pitch away.
    This connection forms a simple wave winding.

In full gap winding: (WBSETCL Technician 2023)

  • Coil gap = pole gap
  • Coil gap < pole gap
  • Coil gap > pole gap
  • Coil gap = Back gap

Explanation:

  • Full pitch winding –
    When winding pitch equals pole pitch, it is a full pitch winding.
    Its pitch factor is unity.
    Coil pitch = pole pitch.

What is the relation between the coil pitch and the pole pitch in a full-gap winding? (UPPCL TG-2, 10.11.2023, Shift-I)

  • Coil gap = pole gap
  • Coil gap < pole gap
  • Coil gap = back gap
  • Coil gap > pole gap

Explanation:

  • Full pitch relation –
    In full pitch winding, coil pitch = pole pitch.
    Full pitch = 180° electrical.
    Pitch factor is unity.
    Pole pitch = slots / poles.

How many parallel paths are there in simplex wave windings armature of DC generator with 8 poles? (UPPCL TG-2, 8.11.2023, Shift-I)

  • 2
  • 4
  • 6
  • 8

Explanation:

  • Parallel paths –
    Wave winding: A = 2m.
    Lap winding: A = mP.
    For simplex winding m = 1, so wave winding has A = 2.

A 12 pole lap wound DC generator has 48 numbers of armature conductors. Find the pole pitch? (UPPCL TG-2, 10.11.2023, Shift-I)

  • 2
  • 12
  • 4
  • 24

Explanation:

  • Pole pitch –
    Pole pitch = number of conductors / number of poles.
    Pole pitch = 48/12 = 4.

Which of the following characteristics is NOT TRUE for Lap winding? (UPPCL TG-2, 10.11.2023, Shift-I)

  • Back pitch is equal to front pitch
  • Commutator pitch is + 1 for progressive winding and – 1 for retrogressive winding
  • The back pitch & front pitch should be odd one
  • Average pitch = (back pitch + front pitch)/2

Explanation:

  • Lap winding pitches –
    Back and front pitches are odd and of opposite sign.
    They cannot be equal; they differ by 2 or a multiple of 2.
    Average pitch Ya = (YB + YF)/2.
    Commutator pitch YC = ±1 (in general ±m).
    Resultant pitch YR = YB – YF, which is even.

In which of the following windings do the beginning and terminating ends of a coil cross each other causing short circuit? (UPPCL TG-2, 03.11.2023, Shift-I)

  • Lap winding
  • Progressive winding
  • Wave winding
  • Retrogressive winding

Explanation:

  • Retrogressive winding –
    The coil leads cross each other and the winding moves opposite to the direction of progress.
    Commutator pitch YC = –1.
    It moves anticlockwise when viewed from the commutator side and is also called left-hand winding.
    In progressive winding, YB > YF and YC = +1.
    YB = Z/P + 1 and YF = YB – 2m.
    Progressive winding is also called right-hand winding.

Usually Lap winding is preferred for ________ voltage and ________ current DC machines. (UPRVUNL (TG-2) 21.12.2022, Shift-II)

  • Small, Large
  • Large, large
  • Small, small
  • Large, small

Explanation:

  • Lap and wave winding –
    Lap winding is preferred for low voltage, high current D.C. machines.
    Lap: A = mP and YR = YB – YF.
    YB and YF are both odd.
    Equalizer rings equalize the current in the parallel paths.
    Wave: A = 2m and YR = YB + YF.
    Dummy coils are used in wave winding for mechanical balance.
    Wave winding is used for high voltage and low current.

Wave winding is generally used for ________ voltage and ________ current machines. (UPRVUNL (TG-2) 21.12.2022, Shift-II)

  • High, low
  • Low, low
  • Low, high
  • High, high

Explanation:

  • Wave winding –
    It is used for high voltage and low current.
    Simplex wave winding has A = 2 and two brushes are sufficient.
    It is also called series winding.
    Lap winding is used for low voltage and high current.
    Lap winding has A = P, brushes equal to the number of paths, and is also called parallel winding.

For a commutator machine with 6 pole and 40 coils, determine the number of commutator segments for a simplex lap winding. (UPRVUNL (TG-2) 21.12.2022, Shift-II)

  • 20
  • 60
  • 80
  • 40

Explanation:

  • Commutator segments –
    In simplex lap winding, commutator segments = number of coils.
    Number of coils = 40, so segments = 40.

Single-layer coils can be arranged in ________ (UPRVUNL TG-2 22.12.2022, Shift-II)

  • Integral slots
  • Semi-closed slots
  • Open slots
  • Fully closed slots

Explanation:

  • Types of slots –
    Single-layer coils can be arranged in semi-closed slots.
    The three slot types are open, closed and semi-closed.
    Semi-closed slots are commonly used in practical machines.

For a 4 pole machine wave winding is impossible with armature conductors of- (KPSC Electrician–07.05.2022)

  • 34
  • 32
  • 30
  • 38

Explanation:

  • Condition for wave winding –
    (Z ± 2)/P must be an integer.
    For Z = 34, 36/4 = 9, so it is possible.
    For Z = 32, 34/4 = 8.5 and 30/4 = 7.5, so it is impossible.
    For Z = 30, 32/4 = 8, so it is possible.
    For Z = 38, 40/4 = 10, so it is possible.

Where is field winding mounted in a DC machine? (KPSC Electrician–07.05.2022)

  • Stator
  • Rotor
  • Absent
  • Any where on stator or rotor

Explanation:

  • Field winding –
    In a D.C. machine, the field winding is mounted on the poles of the stator.
    Series field winding is made of thick wire with few turns.
    It carries a large current.

Which statement is false regarding short pitch winding? (ISRO TA-03.11.2022)

  • Saves copper for end connections
  • Increases efficiency
  • Reduces harmonics
  • Increases volt per turn

Explanation:

  • Short pitch winding –
    It saves copper in the end connections.
    It increases efficiency and reduces harmonics.
    Eddy current and hysteresis losses are reduced.
    It improves the waveform of the generated EMF.
    Its disadvantage is that the total induced voltage is reduced.

How many parallel paths are there in a triplex wave winding? (NVS Electrician Cum Plumber Instructor 08.03.2022)

  • 2
  • 3
  • 5
  • 6

Explanation:

  • Multiplex wave winding –
    A = 2m.
    m = 1 (simplex), 2 (duplex), 3 (triplex).
    For triplex wave winding, A = 2 × 3 = 6.

The pole pitch of a 10 pole motor is 2. Find the number of slots? (ISRO DT. 10.02.2019)

  • 10
  • 20
  • 5
  • None of these

Explanation:

  • Pole pitch –
    Pole pitch = number of slots / number of poles.
    2 = slots/10.
    Number of slots = 20.

Total electrical degrees of a 4 pole motor is? (ISRO DT. 10.02.2019)

  • 720°
  • 320°
  • 180°
  • 1440°

Explanation:

  • Electrical degrees –
    θe = (P/2) × θm
    θe = (4/2) × 360°
    θe = 720°

Which among the following is the purpose of using damper winding in alternator? (Bihar TG-2, 04.11.2018, Batch-1)

  • To boost the speed of alternator
  • To reduce hunting effect
  • To reduce the armature reaction effect
  • To provide starting torque

Explanation:

  • Damper winding –
    It is used in alternators to reduce hunting.
    Hunting occurs when a heavy load is suddenly applied or removed.
    The winding is placed in the rotor pole faces.
    It has copper bars short-circuited at both ends by heavy copper rings.

Read the following statements and choose the CORRECT option.
(i) Short pitch windings used in synchronous motors reduces distorting harmonics.
(ii) Short pitch windings used in synchronous motors require less overhang copper, hence are economical. (Bihar TG-2, 04.11.2018, Batch-1)

  • (i) is TRUE and (ii) is FALSE
  • (i) is FALSE and (ii) is FALSE
  • (i) is TRUE and (ii) is TRUE
  • (i) is FALSE and (ii) is TRUE

Explanation:

  • Short pitch winding in synchronous motor –
    It reduces distorting harmonics.
    It needs less overhang copper, so it is economical.
    A synchronous motor runs at constant speed.
    It is a doubly excited motor.
    D.C. supply is given to its field winding.

Generally concentric winding is used in: (UPPCL TG-2 (Date: 24-01-2019) Shift-I)

  • Single phase motor
  • Transformers
  • Three phase motor
  • DC motor

Explanation:

  • Concentric winding –
    It is generally used in single phase motors.
    All coils of a coil group are concentric.
    The coils are not placed over each other.
    Adjacent coils differ in coil pitch by two slots.
    It needs more work but gives more cooling space.

Mostly which type of winding is generally used in most single phase motors (UPPCL TG-2 (Date: 24-01-2019) Shift-I)

  • Basket winding
  • Concentric winding
  • Diamond winding
  • Chain winding

Explanation:

  • Winding of single phase motors –
    Concentric winding is used in most single phase motors.
    All coils of a coil group are concentric.
    It needs more space but provides more cooling space.

In A.C. winding what is the ratio of pitch factor? (UPPCL TG-2 (Date: 24-01-2019) Shift-II)

  • Pole gap/winding pitch
  • Winding gap – pole pitch
  • Back/pole pitch
  • Winding pitch/pole pitch

Explanation:

  • Pitch factor –
    Among the options, it is expressed as winding pitch/pole pitch.
    It is measured as the resultant EMF of a short-pitched coil divided by that of a full-pitched coil.

If the coil width is less than the pole gap then the winding is called– (UPPCL TG-2 (Date: 25-01-2019) Shift-I)

  • Fractional-pitched
  • Full-pitched
  • Half-pitched
  • Whole-pitched

Explanation:

  • Fractional pitch coil –
    A coil narrower than the pole pitch is a fractional pitch coil.
    Its span is less than the angular distance between the centres of adjacent poles.
    One advantage is reduced sparking.

What is the definition of pole pitch? (UPPCL TG-2 (Date: 25-01-2019) Shift-I)

  • The pole of conductor in a slot at the end of the armature.
  • The number of slot spanned by two poles at the front end of the armature.
  • Number of armature slots per pole
  • Distance between the pitch of the first coil and its next leading coil.

Explanation:

  • Pole pitch –
    It is the peripheral distance between the centres of two adjacent poles.
    Pole pitch = number of armature slots / number of poles.
    One pole pitch is always 180° electrical.
    θelectrical = (P/2) × θmechanical

In a DC machine, the number of parallel path will be equal to the number of poles. If the armature winding are – (UPPCL TG-2 (Date: 25-01-2019) Shift-I)

  • field winding
  • lap and wave winding
  • wave winding
  • lap winding

Explanation:

  • Lap winding –
    In simplex lap winding, parallel paths equal the number of poles.
    Successive coils overlap each other.
    It is called lap winding because it laps back over the succeeding coils.

Total induced EMF in a coil equal to the ________ of induced EMF in both the arms of coil. (UPPCL TG-2 (Date: 25-01-2019) Shift-II)

  • Equal
  • Addition
  • Subtraction
  • Product

Explanation:

  • EMF of a coil –
    Total coil EMF is the addition of the EMFs of both coil sides.
    Vaa’ = E + E = 2E (full pitch coil).
    E is the EMF induced in one coil side.

What is the distance between two consecutive turns called? (UPPCL TG-2 (Date: 25-01-2019) Shift-II)

  • Coil pitch
  • Back pitch
  • Front pitch
  • Resultant pitch

Explanation:

  • Armature winding pitches –
    As per the key, this distance is called coil pitch.
    Coil pitch is also known as coil span.
    Back pitch (YB) is the advance of a coil on the back of the armature.
    Front pitch (YF) is the span on the front side.
    Resultant pitch (YR) is the distance between the starts of two successively connected coils.

The no. of parallel path in a 4-pole, simplex lap-wound armature is– (NMRC Maintainer 07.03.2017, 12.00–02.15 pm)

  • 6
  • 8
  • 4
  • 2

Explanation:

  • Parallel paths in lap winding –
    A = mP.
    P = 4 and m = 1.
    A = 1 × 4 = 4.
    For wave winding, A = 2m.

What’s reason when a low current is carried in a shunt field coil, but a very strong magnetic field is produced? (DMRC Maintainer 09.04.2018, 9.00-10:30 am)

  • Less number of turns
  • Large number of turns
  • High resistance of the coil
  • Thick winding wire

Explanation:

  • Shunt field coil –
    A large number of turns produces a strong field even with low current.
    The shunt field has many turns of thin wire.
    The series field uses thick conductors or strips to carry heavy current.

In three-phase AC stator winding, the number of coils per group is equal to: (DMRC Maintainer 09.04.2018, 9.00-10:30 am)

  • Number of phases per number of poles
  • Zero
  • Number of total coils per number of poles
  • Total number of coils per groups

Explanation:

  • Coil group –
    Coils joined in series to form a unit make a coil group.
    Number of coil groups = poles × phases.
    Coils per group = total coils / number of coil groups.
    Slots per pole per phase = slots / (poles × phases).
    If this value is an integer, it is an integral slot winding.

The data that should be known before winding or rewinding of an AC stator is: (DMRC Maintainer 09.04.2018, 9.00-10:30 am)

  • Number of poles and phase connections
  • Electrical degrees
  • Power loss
  • Phase displacement

Explanation:

  • Data for rewinding –
    The number of poles and the phase connection must be known first.
    They help decide the turns per pole and the type of winding, such as concentric or distributed.

In which winding the distance between two sides of the coil is less than the full pitch winding is called? (DMRC Maintainer 10.04.2018, 9.00-10:30 am)

  • Short pitch winding
  • Pole pitch winding
  • Front pitch winding
  • Back pitch winding

Explanation:

  • Short pitch winding –
    The coil sides are closer than in a full pitch winding.
    It needs less copper for end connections.
    It improves the EMF waveform, bringing it closer to a sine wave.
    Distorting harmonics can be reduced or eliminated.

In short pitch winding method the width of the coil without spark is kept less than the width of the – (DMRC Maintainer 13.04.2018, 9-10:30 am)

  • winding
  • armature
  • pole
  • brush

Explanation:

  • Short pitch method –
    The coil width is kept less than the pole width (pole pitch).
    A winding with pitch factor below unity is short pitched.
    It is used in most motors.
    It saves copper, improves efficiency and occupies less space.

In which of the following winding the coils overlap and the armature rotates in the reverse direction after placing the coil? (DMRC Maintainer 17.04.2018, 9.00-10:30 am)

  • Multiple winding
  • Wave winding
  • Simplex wave winding
  • Lap winding

Explanation:

  • Lap winding –
    The coils overlap in lap winding.
    The armature is turned in the reverse direction after placing a coil.
    Lap winding is used for high current and low voltage.
    Wave winding is used for high voltage and low current.

Which of the following insulating materials is used in electrical winding? (DMRC Maintainer 17.04.2018, 9.00-10:30 am)

  • Rubber
  • Press Pan
  • Fiber glass
  • Marble

Explanation:

  • Winding insulation –
    Press pan (pressboard) insulation is used in electrical windings.
    An insulator should have high resistivity and negligible free electrons.
    Good thermal conductivity is desirable.
    Insulators are generally non-metals.
    Impregnated paper is widely used in H.V. and E.H.V. land cables.
    Polymer insulation is preferred in new D.C. and submarine installations.

The vector sum of the emf spread across several slots under a pole and the induced emf is the ratio of the arithmetic sum of– (DMRC Maintainer 17.04.2018, 9.00-10:30 am)

  • Pitch factor
  • Distribution factor
  • Form factor
  • Coil span factor

Explanation:

  • Distribution factor –
    Kd = phasor sum of coil EMFs / arithmetic sum of coil EMFs.
    It is also called breadth, belt or spread factor.
    Kd = sin(mβ/2) / (m sin(β/2))
    m = slots per pole per phase.
    β = angular displacement between slots.

A complete coil winding in which the number of coil groups per phase is equal to the coil group in the stator and that number is divided by a number representing the total number of phases for which the winding has taken place, such a winding is called? (DMRC Maintainer 17.04.2018, 9.00-10:30 am)

  • Concentric winding
  • Full coil winding
  • Balanced winding
  • Distributed winding

Explanation:

  • Full coil winding –
    Coil groups per phase = total coil groups in the stator / number of phases.
    A complete winding of this kind is called full coil winding.

Which among the following windings is one in which the number of coils per phase is equal to the number of poles in the machines? (Bihar TG-2, 04.11.2018, Batch-2)

  • Whole coil winding
  • Concentrated winding
  • Half coil winding
  • Distributed winding

Explanation:

  • Whole coil winding –
    The number of coils per phase equals the number of poles.
    It is also called full coil winding.

Read the following statements and choose the CORRECT option.
(i) Lap winding is preferred for D.C. generators with high current rating.
(ii) Wave winding is preferred for low current, high voltage D.C. generators (Bihar TG-2, 28.11.2018, Batch-2)

  • (i) is TRUE and (ii) is FALSE
  • (i) is TRUE and (ii) is TRUE
  • (i) is FALSE and (ii) is TRUE
  • (i) is FALSE and (ii) is FALSE

Explanation:

  • Choice of winding –
    In lap winding, successive coils overlap.
    Its parallel paths and brushes equal the number of poles (simplex).
    It suits high current, low voltage machines.
    Simplex wave winding has two parallel paths and needs two brushes.
    It suits low current, high voltage machines.

A 8 pole 90 slots, 4 circuit, duplex winding has 6 coil sides per slot, 270 coils and commutator segments. The commutator pitch will be: (Bihar TG-2, 03.11.2018, Batch-2)

  • 136
  • 134
  • 68
  • 67

Explanation:

  • Commutator pitch –
    Number of coils = commutator segments = 270.
    YC = (segments ± m) / pairs of poles, with m = 2.
    Pairs of poles = 4.
    (270 + 2)/4 = 68 and (270 – 2)/4 = 67.
    The odd value is taken, so YC = 67.

The ends coming out from a coil are known as. (Bihar TG-2, 03.11.2018, Batch-2)

  • Inactive coil
  • Active coil
  • Coil pitch
  • Leads of coil

Explanation:

  • Coil leads –
    The ends coming out of a coil are called its leads.
    The connection joining two coil conductors is the overhang.
    It may be an upper or lower overhang.

Which of the following option is INCORRECT with reference to distributed winding used in A.C machines? (Bihar TG-2, 03.11.2018, Batch-2)

  • The armature reaction and armature reactance are diminished
  • The distorting harmonics cannot be eliminated
  • The even distribution on conductor help in better cooling
  • The waveform of the induced emf is more sinusoidal in nature

Explanation:

  • Harmonics and distributed winding –
    Saying that distorting harmonics cannot be eliminated is incorrect.
    Harmonics are reduced by distribution and can be eliminated by suitable short pitching.
    For the nth harmonic, Kpn = cos(nα/2).
    To eliminate it, nα/2 = π/2, so α = π/n.
    α = short-pitch angle.

The distribution factor for 36-slots, 6-pole, single-layer-three-phase winding is (Given sin 15° = 0.2588)? (Bihar TG-2, 04.11.2018, Batch-3)

  • 0.966
  • 0.853
  • 0.654
  • 0.321

Explanation:

  • Distribution factor –
    Slots per pole = 36/6 = 6.
    m = 6/3 = 2.
    β = 180°/6 = 30°.
    Kd = sin(mβ/2) / (m sin(β/2))
    Kd = sin 30° / (2 sin 15°)
    Kd = 0.5/0.5176 = 0.966

An orderly arrangement of insulated conductors in the slots of armature cores with their end connection in a specified sequence is called? (Bihar TG-2, 04.11.2018, Batch-3)

  • wiring
  • mixing
  • balancing
  • winding

Explanation:

  • Winding –
    It is an orderly arrangement of insulated conductors in armature slots.
    The ends are connected in a specified sequence and fixed pattern.
    The conductors are distributed around the armature.

Each of the two secondary windings of multiple-winding transformer rated at 12 V, 2.5 A, are connected in series. What is the voltage & current at secondary output terminal? (Bihar TG-2, 03.11.2018, Batch-1)

  • 12 V, 2.5 A
  • 25 V, 2.5 A
  • 24 V, 5A
  • 12 V, 5 A

Explanation:

  • Series connected secondaries –
    Voltages add in series-aiding connection.
    V = 12 + 12 = 24 V.
    Current stays the same in series, so I = 2.5 A.

A 8 pole lap wound D.C machine has 720 armature conductors; the pole covers 70% of pole pitch. The number of conductors of compensating winding in each pole face will approximately be: (Bihar TG-2, 03.11.2018, Batch-1)

  • 56 conductors per pole
  • 14 conductors per pole
  • 28 conductors per pole
  • 8 conductors per pole

Explanation:

  • Compensating winding –
    Zc/pole = (Z/AP) × (pole arc/pole pitch)
    = (720/(8 × 8)) × 0.7
    = 7.875
    So about 8 conductors per pole are needed.

For lap winding the front pitch (Yf) and the back pitch (Yb) should be approximately? (Bihar TG-2, 27.11.2018, Batch-1)

  • More than the pole pitch (Yp)
  • Equal to the pole pitch (Yp)
  • Less than the pole pitch
  • Double than the pole pitch (Yp)

Explanation:

  • Pitches of lap winding –
    YF and YB are nearly equal to the pole pitch.
    Both should be odd numbers.
    YR = YB – YF = ±2m, where m is the multiplicity.
    YB > YF gives progressive winding.
    YB < YF gives retrogressive winding.

The ends coming out from a coil are known as? (Bihar TG-2, 27.11.2018, Batch-1)

  • Leads of coil
  • Inactive coil
  • Coil pitch
  • Active coil

Explanation:

  • Coil leads –
    The ends coming out of a coil are called leads.
    Coil span or coil pitch is the distance between the two sides of a coil.

In lap winding, the number of parallel paths are always: (ALP, Technician 23.01.2019, 04:30-07:00)

  • Same as the number of poles
  • Half the number of poles
  • Double the number of poles
  • Two

Explanation:

  • Parallel paths in lap winding –
    For simplex lap winding, A = P.
    A = parallel paths and P = poles.
    Lap winding is used for high current, low voltage applications.

The number of parallel path in 8 pole simplex lap wound armature D.C. generator? (ALP, Technician 22.01.2019, 04:30-07:00)

  • 4
  • 16
  • 2
  • 8

Explanation:

  • Simplex lap winding –
    A = P = 8.
    In simplex lap winding, paths equal the number of poles.
    In duplex lap winding, paths are twice the number of poles.

If the number of coils per pole per phase in a motor winding is one, then it is called? (THDC Electrician 2015)

  • single layer winding
  • double layer winding
  • concentrated winding
  • distributed winding

Explanation:

  • Concentrated winding –
    It has one coil per pole per phase.
    All the turns of that pole and phase are grouped together.

If the number of coils per pole per phase in a motor winding is more than one which are arranged in different slots, then it is called. (CRPF Constable Tradesman Muzaffarpur Electrician-12.01.2014)

  • single layer winding
  • double layer winding
  • concentrated winding
  • distributed winding

Explanation:

  • Distributed winding –
    It has more than one coil per pole per phase.
    The coil sides are placed in different stator slots.
    Each coil usually has the same pitch.

If the number of pole is 4 and the number of slots is 24, then the value of pole pitch will be- (ESIC Electrician-2016)

  • 8 slots
  • 6 slots
  • 4 slots
  • 2 slots

Explanation:

  • Pole pitch –
    Pole pitch = slots / poles.
    = 24/4 = 6 slots per pole.

In which type of winding placed in a single phase motor? (CRPF Constable Tradesman Uttar Pradesh Electrician-06.01.2013)

  • Concentric
  • Diamond coil
  • Distributed
  • Baspet

Explanation:

  • Single phase motor winding –
    Concentric winding is used in single phase motors.
    Its coils of different sizes share a common centre.
    It provides good cooling space.

If the number of twins in a single layer distributed winding is 24 then the number of slots will be– (HAL Electrician 2015)

  • 48
  • 24
  • 20
  • 12

Explanation:

  • Slots as per the answer key –
    Given number = 24.
    Number of slots = 24/2 = 12.

What is common for all the coils in distributed winding? (Indian Ordnance Factory-07.12.2015)

  • pole pitch
  • length
  • width
  • thickness

Explanation:

  • Distributed winding –
    The pole pitch is the same for all coils.
    Pole pitch is the distance between the centres of two adjacent unlike poles.
    It can be expressed in number of slots.

In 3-phase winding, the coil of each phase are placed on the difference of electrical degrees. (JMRC Electrician 2016)

  • 360°
  • 270°
  • 180°
  • 120°

Explanation:

  • Three phase winding –
    The three phase windings are displaced by 120° electrical.

The number of coils per phase is equal to – (BMRC Electrician-2016)

  • total number of coils / number of phase
  • Number of coils / (Number of Phase × number of poles)
  • total number of coils / (number of phase × number of pole pair)
  • number of slots / number of poles

Explanation:

  • Coils per phase –
    Coils per phase = total number of coils / number of phases.

In a 3-phase induction motor, the number of coils per phase per pole is equal to – (CRPF Overseer Electrician-2013)

  • total number of coils / (number of phase × number of pole)
  • total number of coils / number of phases
  • total number of coils / number of poles
  • (number of phases × number of poles) / total number of coil

Explanation:

  • Coils per phase per pole –
    Coils per phase per pole = total coils / (phases × poles).

In Lap winding the number of parallel path is always ________ to the number of poles? (KPSC Instrucor Electrician 16.09.2020)

  • same
  • thrice
  • twice
  • to half

Explanation:

  • Lap winding paths –
    For simplex lap winding, A = P.
    It is used for low voltage and high current.
    Simplex wave winding has two parallel paths.
    Wave winding is used for high voltage and low current.

The winding in which the turns are distributed in adjacent slots in two or more coils connected in series is called- (DMRC Maintainer 19.02.2020 (9.00-10.30))

  • Full pitch winding
  • Pole winding
  • Fractional pitch winding
  • Distributed winding

Explanation:

  • Distributed winding –
    Turns are spread over adjacent slots using two or more series coils.
    Its induced EMF is less than that of an equivalent concentrated winding.

In ________ winding each slot has only one coil sides- (DMRC Maintainer 17.02.2020 (9.00-10.30))

  • Concentric
  • Triplex
  • Double layer
  • Single layer

Explanation:

  • Single layer winding –
    Each slot has only one coil side.

What is the number of parallel paths in wave windings in DC machines? (HSSC ALM 14.03.2020 Shift-III)

  • One
  • Three
  • Two
  • Five

Explanation:

  • Wave winding paths –
    A = 2m.
    For simplex wave winding (m = 1), A = 2.
    For simplex lap winding, A = P.

In DC generators Lap winding is used for- (RSMSSB Instructor (Wireman) 24.03.2019)

  • High voltage, high current
  • Low voltage, high current
  • High voltage, low current
  • Low voltage, low current

Explanation:

  • Use of lap winding –
    It is used for low voltage, high current generators.
    Equalizer rings equalize the current in the parallel paths.
    It is also called parallel or multiple winding.
    Wave winding is used for high voltage and low current.
    Wave winding uses dummy coils for mechanical balance.
    It is also called series or two-circuit winding.

Wire coil acts as a/an: (RSMSSB Instructor (Wireman) 24.03.2019)

  • Electric plate
  • Electromagnet
  • Electric wire
  • Conductor

Explanation:

  • Electromagnet –
    A wire coil acts as an electromagnet when current flows through it.

A triplex wave winding will have ________ parallel paths (ISRO DT. 02.06.2019)

  • 2
  • 3
  • 6
  • 9

Explanation:

  • Triplex wave winding –
    A = 2m.
    m = 1 (simplex), 2 (duplex), 3 (triplex).
    A = 2 × 3 = 6.
    For lap winding, A = mP.

Which of the following types of windings is NOT used in D.C machines now a days? (Bihar TG-2, 04.11.2018, Batch-1)

  • Lap winding
  • Duplex Lap winding
  • Gramme-ring winding
  • Wave winding

Explanation:

  • Gramme-ring winding –
    It is no longer used in modern D.C. machines.
    Lap winding is used for high current and low voltage.
    Wave winding is used for high voltage and low current.

Which of the following insulating materials is used for impregnation of armature windings? (Bihar TG-2, 04.11.2018, Batch-1)

  • Paint
  • Empire paper
  • Oil
  • Baking varnish

Explanation:

  • Impregnation –
    Baking varnish is used to impregnate armature windings.
    Conductors lie close together in the slots.
    A thin varnish layer helps protect them from short circuits between each other.

The helical coils are generally used for. (Bihar TG-2, 04.11.2018, Batch-1)

  • Low voltage windings of small single phase transformers
  • Low voltage windings of large transformers
  • High voltage windings of large transformers
  • High voltage windings of small transformers

Explanation:

  • Transformer coils –
    Helical coils are used for low voltage windings of large transformers.
    Cross-over coils are used for high voltage windings of small transformers.

In progressive lap or wave winding, the front pitch (YF) will be (Bihar TG-2, 03.11.2018, Batch-3)

  • less than the back pitch (Yb)
  • same as the back pitch (Yb)
  • double than the back pitch (Yb)
  • more than the back pitch (Yb)

Explanation:

  • Progressive winding –
    As per the PDF, front pitch is less than back pitch.
    In progressive lap winding, commutator pitch YC = +1 (simplex).
    The winding advances from left to right.
    The coil leads do not cross each other.

The term back pitch is generally use in the context of- (UPPCL TG-2 (Date: 24-01-2019) Shift-I)

  • DC motor starter winding
  • Alternator winding
  • AC motor winding
  • D.C armature winding

Explanation:

  • Back pitch –
    The term is generally used for D.C. armature winding.
    It is the distance between the two active sides of a coil at the back of the armature.
    It is expressed in slots or conductors.

Torid—- is a (UPPCL TG-2 (Date: 24-01-2019) Shift-I)

  • Coil of wire
  • Coiled coil of wire
  • Loped wire
  • Straight wire

Explanation:

  • Toroid –
    A toroid can be viewed as a coiled coil of wire.
    It is like a solenoid bent into a closed ring.

________ commutator segment are insulated using. (UPPCL TG-2 (Date: 24-01-2019) Shift-I)

  • PVC Tape
  • Mica Insulator
  • Fiber tape
  • Cotton clothes

Explanation:

  • Commutator insulation –
    Commutator segments are insulated from each other with mica.
    The commutator converts A.C. to D.C. in a generator.
    It converts D.C. to A.C. in the armature of a motor.

What is the number of parallel path in a four pole wave winding D.C machine- (UPPCL TG-2 (Date: 25-01-2019) Shift-I)

  • 4
  • 2
  • 8
  • 6

Explanation:

  • Wave winding paths –
    Simplex wave winding always has A = 2.
    In general, wave: A = 2m.
    Lap: A = mP, where m is the multiplicity factor.

In a coil, if the coil span is equal to the pole pitch, then it is called– (UPPCL TG-2 (Date: 25-01-2019) Shift-I)

  • Fractional pitch coil
  • Short pitch coil
  • Full pitch coil
  • Chorded coil

Explanation:

  • Full pitch coil –
    Coil span equals pole pitch (180° electrical).
    Coil pitch is the angular distance between the two sides of a coil.
    If the span is less than a pole pitch, it is a short or fractional pitch coil.

Number of coil sides is ________ of number of coils. (UPPCL TG-2 (Date: 25-01-2019) Shift-II)

  • equal
  • two times
  • four times
  • three times

Explanation:

  • Coil sides –
    Each coil has two coil sides.
    Number of coil sides = 2 × number of coils.
    One turn has two conductors.

In a direct current (D.C.) machine, a 6-pole lap coil is used then what will be the number of parallel paths? (UPPCL TG-2 (Date: 25-01-2019) Shift-II)

  • 6
  • 8
  • 2
  • 4

Explanation:

  • Lap winding paths –
    For simplex lap winding, A = P = 6.
    Simplex wave winding always has A = 2.
    Lap suits low voltage, high current.
    Wave suits high voltage, low current.

In a Lap and wave winding, the number of back pitch (YB) and front pitch (YF) are ________ (UPPCL TG-2 (Date: 25-01-2019) Shift-I)

  • Should be even for Lap winding and odd for wave winding.
  • Should be odd for Lap winding and even for wave winding.
  • Should be even
  • Should be odd

Explanation:

  • Back and front pitch –
    YB and YF are odd in both lap and wave windings.
    Resultant pitch is the distance between the starts of two consecutive coils.
    Lap: YR = YB – YF
    Wave: YR = YF + YB

In a direct current (D.C.) machine, which of the following is correct with respect to the retrogressive coil? (UPPCL TG-2, 10.11.2023, Shift-I)

  • YB = YF + 1
  • YB = YF
  • YB > YF
  • YB < YF

Explanation:

  • Retrogressive winding –
    Front pitch is greater than back pitch (YF > YB).
    In wave winding, if one round ends in a slot left of the start, it is retrogressive.
    If it ends to the right of the start, it is progressive.

How many parallel path are in wave winding? (UPPCL TG-2 (Date: 24-01-2019) Shift-II)

  • 10
  • 6
  • 2
  • 4

Explanation:

  • Wave winding –
    Simplex wave winding has A = 2.
    The two main winding types are lap and wave.
    Lap is used for low voltage, high current.
    Wave is used for high voltage, low current.

In three phase system, phase difference between coil winding. (UPPCL TG-2 (Date: 24-01-2019) Shift-II)

  • 120°
  • 60°
  • 90°
  • 180°

Explanation:

  • Phase difference –
    In a three phase system, the phases differ by 120°.
    For an N-phase system (N ≥ 3), it is 360°/N.
    Three phase windings are connected in star (Y) or delta.
    In a two phase system, the difference is 90°.

The generated e.m.f./path in a simplex lap-wound generator is: (LMRC Maintainer 12.05.2018, Shift–II)

  • (ΦZPN/120) V
  • (ΦZN/60) V
  • (ΦZN/120) V
  • (ΦZPN/60) V

Explanation:

  • EMF equation –
    E = NPΦZ/(60A)
    For simplex lap winding, A = P, so E = ΦZN/60 volt.
    For simplex wave winding, A = 2, so E = NPΦZ/120.
    Ratio of wave EMF to lap EMF = P/2.

The number of parallel paths through armature in a duplex wave wound 6-pole DC machine is: (LMRC Maintainer 12.05.2018, Shift–II)

  • 6
  • 4
  • 12
  • 2

Explanation:

  • Duplex wave winding –
    A = 2m.
    For duplex winding, m = 2.
    A = 2 × 2 = 4.
    For lap winding, A = mP.

The ratio of no. of slots in the stator to the no. of poles is called as: (NMRC Maintainer 07.03.2017, 12.00–02.15 pm)

  • coil pitch
  • pole pitch
  • coil span
  • coil throw

Explanation:

  • Pole pitch –
    YP = slots/poles = S/P, or conductors/poles = Z/P.
    It is the distance on the armature periphery between the centres of adjacent poles.
    Coil pitch is the distance between the two sides of a coil.

In a D.C. motor, the loss through the winding is proportional to?

  • Square of velocity
  • Square of current
  • Square of voltage
  • Square of load

Explanation:

  • Copper loss –
    Copper loss = I2R.
    I = current and R = resistance.
    It is a variable loss that changes with load current.

Which type of wire is used for winding the field coil?

  • Enameled copper wire
  • Stainless steel wire
  • Bare copper wire
  • Steel wire

Explanation:

  • Field coil wire –
    Enameled copper wire is used because copper has high conductivity.
    Resistivity of copper at 20°C = 1.72 × 10−8 Ω–m.
    Temperature coefficient at 20°C = 0.0039/°C.
    Melting point = 1084°C.
    Density = 8.9 g/cc.

Which of the following option is used to the armature winding to the correct size and shape of the armature core? (DMRC Maintainer 10.04.2018, 9.00-10:30 am)

  • Aluminium wire
  • Copper wire
  • Enameled aluminium wire
  • Enameled copper wire

Explanation:

  • Armature winding wire –
    Enameled copper wire is used in armature windings.
    Copper has low resistivity and good current carrying capacity.
    The wire has an insulating coating on its surface.
    Winding coils are further insulated with varnish.

The method in which the armature coil is divided into two parallel paths, irrespective of the number of poles is called ________. (DMRC Maintainer 10.04.2018, 9.00-10:30 am)

  • Progressive winding
  • Wave winding
  • Residual magnetism
  • Lap winding

Explanation:

  • Wave winding –
    It has two parallel paths whatever the number of poles.
    It is also called series or two-circuit winding.
    YB and YF are odd, of the same sign, and may or may not be equal.
    Wave: YR = YB + YF.
    Lap winding is also called parallel or multiple winding.
    In lap winding, the pitches are nearly equal to pole pitch, odd, unequal and of opposite sign.
    Lap: YR = YB – YF.

In which type of winding, the coil and termination edge are connected at a distance of commutator segments? (DMRC Maintainer 10.04.2018, 9.00-10:30 am)

  • duplex wave winding
  • simplex wave winding
  • duplex lap winding
  • simplex lap winding

Explanation:

  • Simplex wave winding –
    The starting and ending leads of a coil connect to segments far apart.
    The end of coil 1 joins the start of another coil about one pole pitch away.
    Number of parallel paths A = 2m.
    m = 1 (simplex), 2 (duplex), 3 (triplex).

The arrangement of insulated conductors in the slots of the armature core is called ________? (DMRC Maintainer 11.04.2018)

  • Lap winding
  • Wave winding
  • Progressive winding
  • Armature winding

Explanation:

  • Armature winding –
    It is the arrangement of insulated conductors in the armature slots.
    Its two main types are lap and wave.
    Lap is used for high current and low voltage.
    Wave is used for low current and high voltage.

A conductor having several turns in series are attached to it, then it is called? (DMRC Maintainer 11.04.2018)

  • Coil group
  • Coil span
  • Coils
  • Coil sides

Explanation:

  • Coil –
    Several turns connected in series form a coil.
    1 turn = 2 conductors.
    Number of conductors = 2 × number of turns.

The distance between the centers of two adjacent poles of a machine is called ________. (DMRC Maintainer 11.04.2018)

  • Front pitch
  • Pitch factor
  • Pole pitch
  • Coil

Explanation:

  • Pole pitch –
    It is the distance between the centres of two adjacent poles.
    YP = Z/P or S/P.
    Pole pitch = 180° electrical.
    Pitch factor Kp = EMF of short pitch coil / EMF of full pitch coil.

If the coil pitch is greater than pole pitch then this type of winding is- (DMRC Maintainer 12.04.2018, 9.00-10:30 am)

  • Long chord pitch
  • Full pitch winding
  • Winding pitch
  • Short chord winding

Explanation:

  • Coil pitch types –
    Coil pitch greater than pole pitch gives long chorded winding.
    Equal pitches give full pitch winding.
    A smaller coil pitch gives short pitch winding.
    Full pitch winding induces more EMF than short pitch winding.

Which of the following material is used in armature winding. (DMRC Maintainer 12.04.2018, 9.00-10:30 am)

  • Plate of gold
  • Mercury
  • Micanite
  • Fluorescent material

Explanation:

  • Micanite –
    It is a mica based insulating material used with paper or cloth backing.
    It withstands high temperature and protects the armature insulation.
    Mica is a naturally occurring mineral that can be split into flat, elastic sheets.
    Mica is used in capacitors, electric irons and commutator insulation.

The relation between the front pitch and the back pitch in the progressive lap winding of the armature is denoted by (DMRC Maintainer 13.04.2018, 9-10:30 am)

  • Positive sign
  • Infinite value
  • Zero
  • Negative sign

Explanation:

  • Sign of commutator pitch –
    Progressive winding takes a positive sign.
    YC = +1 (simplex), +2 (duplex), +3 (triplex).
    Retrogressive winding takes a negative sign: –1, –2, –3.
    Progressive winding is also called right-hand winding.
    Retrogressive winding is also called left-hand winding.

The connection between the interfaces which is called star or delta method or both method is referred to as. (DMRC Maintainer 13.04.2018, 9-10:30 am)

  • group connection
  • adjacent connection
  • coil group
  • phase connection

Explanation:

  • Phase connection –
    Connecting the phases in star or delta is called phase connection.
    In star (Y), similar ends of the three windings are joined at the neutral point N.
    The other ends go to the line wires; with a neutral it is a 3-phase, 4-wire system.
    In delta (Δ), the finish of one phase joins the start of the next to form a closed circuit.

A transformer in which a single winding series as both primary and secondary is called ________. (DMRC Maintainer 13.04.2018, 9-10:30 am)

  • Current
  • Tap changing transformer
  • Voltage transformer
  • Auto transformer

Explanation:

  • Auto transformer –
    A single winding serves as both primary and secondary.
    It works on the principle of self induction.
    It is used in stabilizers, boosters and induction motor starting.
    Power is transferred both inductively and conductively.
    For step-down, inductive power = (1 – K) × input power.
    Conductive power = K × input power.
    K = LV/HV.

Which of the following options can be defined as the ratio of conductor area per slot to slot area? (Bihar TG-2, 03.11.2018, Batch-4)

  • Slot space factor
  • Specific permeance of slot
  • Slot leakage flux
  • Slot pitch

Explanation:

  • Slot space factor –
    Slot space factor = conductor area per slot / slot area.
    Slot pitch is the distance between two adjacent slots.

Which among the following windings in transformer has more cross-sectional area? (Bihar TG-2, 04.11.2018, Batch-3)

  • High voltage winding
  • Low voltage winding
  • Secondary winding
  • Primary winding

Explanation:

  • Conductor area –
    The low voltage winding carries more current.
    For the same current density, area ∝ current.
    So the LV winding has a larger cross-section.
    Higher voltage needs a higher insulation level.

Which among the following windings is one in which the number of coil per phase is equal to the number of poles in the machines? (Bihar TG-2, 27.11.2018, Batch-2)

  • Half coil winding
  • Concentrated winding
  • Whole coil winding
  • Distributed winding

Explanation:

  • Whole coil winding –
    Coils per phase equal the number of poles.
    Single layer: one coil side per slot, so coils = slots/2.
    Single layer: slots = coil sides.
    Double layer: two coil sides per slot, one at the top and one at the bottom.
    Double layer: coil sides = 2 × slots, and coils = slots.

Which of the following options is INCORRECT with reference to distributed windings used in A.C machines? (Bihar TG-2, 27.11.2018, Batch-1)

  • The armature reaction and armature reactance are diminished
  • The even distribution of conductors helps in better cooling
  • The waveform of the induced emf is more sinusoidal in nature
  • The distorting harmonics cannot be eliminated

Explanation:

  • Advantages of distributed winding –
    It reduces armature reaction and armature reactance.
    The EMF waveform is more sinusoidal.
    Distorting harmonics are reduced.
    Copper loss heat is spread evenly, so cooling is better.
    The armature core is fully used.
    The armature is well balanced.

The number of parallel path in 8 pole wave wounded D.C. generator? (BMRC Electrician-2016)

  • 10
  • 4
  • 8
  • 2

Explanation:

  • Wave winding paths –
    A = 2m.
    For simplex winding, m = 1, so A = 2.
    Wave winding suits small generators for about 500–600 V circuits.
    It does not need equalizer rings.
    Lap winding uses equalizer rings.
    Lap front and back pitches are odd, of opposite sign and unequal.

If the pole pitch is 8 and the number of poles is also 8, then the number of armature slots will be (UPRVUNL-TG-2 Electrical-2015)

  • 16
  • 64
  • 8
  • 1

Explanation:

  • Number of slots –
    Slots = poles × pole pitch.
    Slots = 8 × 8 = 64.

In the metric system the size of super enameled copper wire is expressed as? (R.R.B. Siliguri (L.P.)-2014)

  • diameter in mm
  • cross-sectional area in mm2
  • in gauge number
  • resistance in ohms

Explanation:

  • Size of enameled wire –
    In the metric system, it is given as diameter in mm.
    It is also called magnet wire.
    It is used in generator and motor windings.
    Gauge systems include SWG (Standard Wire Gauge) and AWG (American Wire Gauge).
    Enamel insulation prevents accidental short circuits.

Coil separator is the insulator in the winding of small transformer (CRPF Constable Tradesman Muzaffarpur Electrician-12.01.2014)

  • Leatheroid papers
  • Butter paper
  • Presphone paper
  • Milinex paper

Explanation:

  • Leatheroid paper –
    It is an insulating paper used to prevent short circuits in small transformer windings.
    A good insulator has high resistance and high dielectric strength.
    It should have good mechanical strength.
    It should be non-porous and free from impurities.

Super enemaled wire of 0.14 mm dia is used instead of 0.16 mm dia for rewinding of transformer by keeping the number of terms remains same then in this condition: (ESIC Electrician-2016)

  • winding losses will be less
  • the output of the transformer will be less
  • transformer performance will change
  • transformer efficiency will remain unaffected.

Explanation:

  • Effect of thinner wire –
    A thinner wire has a smaller cross-sectional area.
    Its resistance is higher and its safe current is lower.
    So the output rating of the transformer decreases.

For which test of winding is the search coil method adopted? (HAL Electrician 2015)

  • continuity test of coil
  • short circuit test of coil
  • polarity of pole
  • resistance of coil

Explanation:

  • Search coil method –
    As per the key, it is used to test pole polarity.
    A search coil used with a flux meter helps find the polarity of a magnet or pole.

Which one of the following varnishes is used in case of emergency in armature rewinding work. (BMRC Electrician-2016)

  • Baking varnish
  • Air dry varnish
  • Thermosetting varnish
  • Solventless varnish

Explanation:

  • Air drying varnish –
    It is used for urgent rewinding work.
    Varnish protects the winding from contamination and short circuits.
    It also makes the winding mechanically rigid.
    Methods include dip and bake, trickle, VPI (Vacuum Pressure Impregnation) and ultra-seal.

Which type of slot used in a small D.C. motor? (CRPF Constable Tradesman Mokamghat Electrician-05.01.2014)

  • Open slot
  • Closed slot
  • Semi-closed slot
  • ‘Dovetail’ type open slot

Explanation:

  • Comparison of slots –
    Semi-closed slots are used in small D.C. motors.
    Magnetising current: open > semi-closed > closed.
    Leakage reactance: open < semi-closed < closed.
    Starting torque: open > semi-closed > closed.
    No-load power factor: open < semi-closed < closed.
    Semi-closed slots reduce the effective air gap and give more uniform flux with fewer harmonics than open slots.

The best method for testing the mutual ‘short-circuit’ of turns in a single coil in the armature winding is? (UKSSSC Electrician Instructor 16.06.2019)

  • Ohm-meter method
  • Test-lamp method
  • Voltage drop method
  • Wheat stone bridge method

Explanation:

  • Voltage drop method –
    A supply is passed through the armature winding.
    The voltage drop is compared between adjacent commutator segments.
    A coil with shorted turns shows a lower voltage drop.

Which method is used for ‘earth fault test’ of armature winding? (CRPF Constable Tradesman Kathgodam Electrician-07.04.2013)

  • Growler test method
  • Series test lamp method
  • Voltage drop method
  • All these three method

Explanation:

  • Earth fault test –
    Growler, series test lamp and voltage drop methods can be used.
    A growler has a coil on an iron core fed with A.C.
    It is widely used to find shorted coils in armatures.

The difference between lap and wave winding. (JMRC Electrician 2016)

  • in number of parallel paths
  • in direction of current flow
  • in direction of induced E.M.F.
  • none of these

Explanation:

  • Lap and wave difference –
    They differ in the number of parallel paths.
    Simplex lap: A = P.
    Simplex wave: A = 2.
    Lap is used for low voltage, high current.
    Wave is used for high voltage, low current.

The number of parallel paths in a 4 pole wave wound dc machine is (Gujrat Electrical Instructor 01.01.2022)

  • 4
  • 2
  • 8
  • 1

Explanation:

  • Wave winding paths –
    Simplex wave winding has 2 parallel paths.
    In general, wave: A = 2m.
    Lap: A = mP.

If the armature winding in the DC machine is wave type winding, number of parallel paths for wave (A) will be (DSSSB Craft Instructor (ESM) 06-10-2019)

  • A = P
  • A = 0
  • A = 2
  • A = P/2

Explanation:

  • Simplex wave winding –
    A is always 2.
    Wave winding is also called series winding.
    It is used for high voltage and low current.
    Lap winding is also called parallel winding.
    It is used for low voltage and high current.

What is the coil throw, if the coil pitch is 12? (KPSC Lineman-10.12.2015)

  • 24
  • 6
  • 10
  • 12

Explanation:

  • Coil throw –
    Coil pitch is also expressed as coil throw, so the throw is 12.
    It is the distance between the two active sides of a coil lying under unlike poles.
    It is also called winding pitch or coil span.

The most common method to test the armature winding for short and open coils is (KPSC Lineman 07.02.2018)

  • Insulation resistance test
  • Drop test
  • Growler test
  • Ground test

Explanation:

  • Growler test –
    It is the most common test for shorted and open armature coils.
    The two types are internal and external growlers.
    An external growler tests small armatures.
    An internal growler is used for large D.C. armatures and A.C. stator windings.

Which of the following statements is correct regarding wave winding? (NVS Electrician Cum Plumber Instructor 08.03.2022)

  • Front pitch may be odd or even
  • Average pitch should be an even integer
  • Back pitch is always even
  • Back pitch and front pitch are of opposite sign.

Explanation:

  • Wave winding pitches –
    YB and YF are odd and of the same sign.
    YR = YB + YF.
    Average pitch YA = (Z ± 2m)/P.
    YA must be an integer.

In lap winding no. of brushes is always ________ The no. of pole. (GSSSB Supervisor Instructor 15.09.2019)

  • Double
  • same as
  • half
  • none of the above

Explanation:

  • Brushes in lap winding –
    The number of brushes equals the number of poles.
    Lap (parallel) winding is used for low voltage, high current.
    Wave winding needs a minimum of two brushes.
    Wave (series) winding is used for high voltage, low current.

The number of parallel path for 4 pole duplex lap winding is (GSSSB Supervisor Instructor 15.09.2019)

  • 4
  • 8
  • 6
  • 2

Explanation:

  • Duplex lap winding –
    A = mP.
    m = 2 and P = 4.
    A = 2 × 4 = 8.
    Front and back pitches are odd.
    Average pitch YA = (YB + YF)/2.

The dummy coil in d.c. machine are useful to (GSSSB Supervisor Instructor 15.09.2019)

  • increase the efficiency
  • improve the commutation
  • reduce the cost of machine
  • maintain the mechanical balance of armature

Explanation:

  • Dummy coil –
    It keeps the armature mechanically balanced.
    It is used in wave wound machines.
    It is not electrically connected to the commutator.

A 4 pole generator with 16 coils has two layer lap winding the pole pitch is (GSSSB Supervisor Instructor 15.09.2019)

  • 32
  • 16
  • 8
  • 4

Explanation:

  • Pole pitch –
    Coil sides (single-turn coils) = 2 × 16 = 32.
    Pole pitch = 32/4 = 8.

What would be the coil span, if the span of the coil is reduced by α electrical degrees? (HSSC Electrical Instructor 12.12.2019)

  • 90 + α
  • 180 – α
  • 180 + α
  • 90-α

Explanation:

  • Coil span –
    It is the distance between the two active sides of a coil in slots, conductors or electrical degrees.
    Full coil span = 180° electrical.
    When reduced by α, coil span = 180° – α.

A contactor coil is designed for 220V DC. What happens if it is connected to 220 V AC? (KPSC Electrician (Waters tranproof) 25.02.2016)

  • Too large a current is drawn by the coil and it is destroyed
  • Too small current is drawn by the coil and the operation of the contactor is no longer certain
  • It draws the same current
  • It works better

Explanation:

  • DC coil on AC supply –
    On AC, inductive reactance adds to the coil resistance.
    The higher impedance makes the coil draw much less current.
    So the contactor may not operate reliably.

A wave winding must go at least ________ around the armature before it closes back where it started. (DSSSB Craft Instructor wireman 01.09.2019)

  • Once
  • Twice
  • Thrice
  • Four times

Explanation:

  • Closing of wave winding –
    It goes at least twice around the armature before closing.
    D.C. windings are mainly lap and wave.
    Simplex lap: A = P; it is also called parallel winding.
    Simplex wave: A = 2; it is also called series winding.

The DC armature winding in which coil sides are a pole pitch apart is called ________ winding (DSSSB Craft Instructor wireman 01.09.2019)

  • Multi Pitch
  • Fractional pitch
  • Full pitch
  • Short pitch

Explanation:

  • Full pitch winding –
    The coil sides are one pole pitch apart.
    Pole pitch is the distance between two adjacent poles.

Equilizer rings are required in case the armature is having ________ winding (ISRO (SDSC) Technician (B) 29.04.2018, 2:30-4:00PM)

  • Lap winding
  • Wave winding
  • Delta winding
  • Duplex winding

Explanation:

  • Equalizer rings –
    They are required in lap wound armatures.
    They prevent unequal current distribution at the brushes.
    They reduce sparking between brushes and commutator.
    They are low resistance copper conductors.
    They join points in the winding that should be at the same potential.
1.ALP/Locopilot CBT 2 Part B – Electrician Electrical AC and DCQuestion bank #25